{"id":118320,"date":"2023-08-25T07:26:20","date_gmt":"2023-08-25T05:26:20","guid":{"rendered":"https:\/\/www.velasolaris.com\/handbuch\/reglage-du-circuit-de-chauffage\/"},"modified":"2023-10-25T17:21:10","modified_gmt":"2023-10-25T15:21:10","slug":"reglage-du-circuit-de-chauffage","status":"publish","type":"handbuch","link":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/","title":{"rendered":"R\u00e9glage du circuit de chauffage"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Le r\u00e9glage du circuit de chauffage r\u00e9gule l&rsquo;\u00e9tat et le d\u00e9bit d&rsquo;une pompe en fonction de la sp\u00e9cification de la simulation du b\u00e2timent. En option, une vanne m\u00e9langeuse peut \u00e9galement \u00eatre r\u00e9gl\u00e9e.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Il dispose de 4 (plus 3 en option) entr\u00e9es analogiques<\/li>\n\n\n\n<li>Il dispose de 2 sorties (plus 2 en option), en partie num\u00e9riques et en partie analogiques<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Activation et d\u00e9sactivation du circuit de chauffage en fonction du r\u00e9glage de la temp\u00e9rature ambiante par thermostat. La temp\u00e9rature aller est calcul\u00e9e sur la base de la temp\u00e9rature ext\u00e9rieure. La temp\u00e9rature aller est utilis\u00e9e comme temp\u00e9rature nominale pour la vanne m\u00e9langeuse. <a><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"Le-sch\u00e9ma-fonctionnel\" style=\"font-size:30px\"><strong>Le sch\u00e9ma fonctionnel<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Le sch\u00e9ma fonctionnel montre quelles variables mesur\u00e9es et quelles variables manipul\u00e9es sont raccord\u00e9es.<\/p>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-7387b849 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/www.velasolaris.com\/wp-content\/uploads\/2023\/10\/figure145.png\" alt=\"\" class=\"wp-image-75850\"\/><figcaption class=\"wp-element-caption\">Figure: Sch\u00e9ma fonctionnel des variables mesur\u00e9es\/de fonctionnement pour le r\u00e9glage du circuit de chauffage<\/figcaption><\/figure>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"Param\u00e9trage-de-r\u00e9glage\" style=\"font-size:30px\"><strong>Param\u00e9trage de r\u00e9glage<\/strong><\/h2>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-7387b849 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.velasolaris.com\/wp-content\/uploads\/2023\/10\/image207-1-1024x708.png\" alt=\"\" class=\"wp-image-75859\"\/><figcaption class=\"wp-element-caption\">Figure: Onglet d&rsquo;entr\u00e9e du r\u00e9glage<\/figcaption><\/figure>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"Valeurs-d'entr\u00e9e\" style=\"font-size:30px\"><strong>Valeurs d&rsquo;entr\u00e9e<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Temp\u00e9rature-ext\u00e9rieure-[\u00b0C]\">Temp\u00e9rature ext\u00e9rieure [\u00b0C]<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La valeur indique quelles donn\u00e9es m\u00e9t\u00e9orologiques sont mesur\u00e9es. Indiquez soit les donn\u00e9es m\u00e9t\u00e9orologiques de la temp\u00e9rature ext\u00e9rieure, soit la temp\u00e9rature ext\u00e9rieure moyenne sur 24 heures.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Temp\u00e9rature-nominale-pi\u00e8ces-[\u00b0C]\">Temp\u00e9rature nominale pi\u00e8ces [\u00b0C]<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La valeur indique la hauteur de la temp\u00e9rature nominale en pr\u00e9sence de personnes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Temp\u00e9rature-ambiante-r\u00e9elle-[\u00b0C]\">Temp\u00e9rature ambiante r\u00e9elle [\u00b0C]<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La valeur indique le niveau de la temp\u00e9rature moyenne r\u00e9elle des pi\u00e8ces.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"D\u00e9bit-r\u00e9gl\u00e9-[l\/h]\">D\u00e9bit r\u00e9gl\u00e9 [l\/h]<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cette valeur indique le d\u00e9bit des convecteurs raccord\u00e9s. Sp\u00e9cifiez le \u00ab\u00a0D\u00e9bit nominal total\u00a0\u00bb du convecteur. Il est calcul\u00e9 \u00e0 partir de la propri\u00e9t\u00e9 catalogue du convecteur et du nombre de convecteurs.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Temp\u00e9rature-nominale-variable-(n\u00e9cessaire-pour-la-vanne-m\u00e9langeuse)\">Temp\u00e9rature nominale variable (n\u00e9cessaire pour la vanne m\u00e9langeuse)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Entrez ici la temp\u00e9rature aller nominale du convecteur. Cela d\u00e9termine la temp\u00e9rature d&rsquo;aller maximale.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Niveau-de-temp\u00e9rature-sup\u00e9rieur-(n\u00e9cessaire-pour-la-vanne-m\u00e9langeuse)\">Niveau de temp\u00e9rature sup\u00e9rieur (n\u00e9cessaire pour la vanne m\u00e9langeuse)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cette valeur indique dans quel composant est mesur\u00e9 le niveau de temp\u00e9rature sup\u00e9rieur pour la vanne m\u00e9langeuse. S\u00e9lectionnez le tube d&rsquo;entr\u00e9e correspondant sur la vanne m\u00e9langeuse ou <strong>la raccord pr\u00e9c\u00e9dente au r\u00e9servoir<\/strong>. (Correspondant \u00e0 celui de la vanne m\u00e9langeuse de r\u00e9glage).<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Niveau-de-temp\u00e9rature-inf\u00e9rieure-(n\u00e9cessaire-pour-la-vanne-m\u00e9langeuse)\">Niveau de temp\u00e9rature inf\u00e9rieure (n\u00e9cessaire pour la vanne m\u00e9langeuse)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La valeur indique dans quel composant le niveau de temp\u00e9rature le plus bas est mesur\u00e9. S\u00e9lectionnez le tube correspondant sur la vanne m\u00e9langeuse \u00e0 l'\u00a0\u00bbEntr\u00e9e X\u00a0\u00bb. (Correspondant \u00e0 celui de la vanne m\u00e9langeuse de r\u00e9glage)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"Description-des-param\u00e8tres-de-r\u00e9glage\" style=\"font-size:30px\"><strong>Description des param\u00e8tres de r\u00e9glage<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Description\">Description<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La \u00ab\u00a0valeur\u00a0\u00bb de la description peut \u00eatre utilis\u00e9e pour attribuer un nom ou un num\u00e9ro quelconque au r\u00e9glage. Par d\u00e9faut, Polysun attribue un num\u00e9ro cons\u00e9cutif, chronologique au nombre de r\u00e9glages ins\u00e9r\u00e9s dans l&rsquo;hydraulique.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Signe-de-la-sortie\">Signe de la sortie<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Normal signifie que les signaux de sortie num\u00e9riques sont contr\u00f4l\u00e9s comme pr\u00e9vu dans la logique de commutation. Invers\u00e9 signifie que les signaux de sortie num\u00e9riques sont multipli\u00e9s par -1.<strong><br><\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Activation-du-circuit-de-chauffage-[\u00b0C]\">Activation du circuit de chauffage [\u00b0C]<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si la temp\u00e9rature ext\u00e9rieure est inf\u00e9rieure \u00e0 la valeur sp\u00e9cifi\u00e9e, la temp\u00e9rature aller est calcul\u00e9e sur la base de la temp\u00e9rature ext\u00e9rieure et de la temp\u00e9rature aller nominale. Si la temp\u00e9rature ext\u00e9rieure d\u00e9passe la valeur sp\u00e9cifi\u00e9e, la temp\u00e9rature aller est r\u00e9gl\u00e9e sur une valeur minimale.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Hyst\u00e9r\u00e9sis-mise-en-marche\">Hyst\u00e9r\u00e9sis mise en marche<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La pompe du circuit de chauffage est activ\u00e9e lorsque la temp\u00e9rature ambiante r\u00e9elle est inf\u00e9rieure \u00e0 la temp\u00e9rature ambiante nominale plus l&rsquo;hyst\u00e9r\u00e9sis de mise en marche.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Hyst\u00e9r\u00e9sis-d\u2019arr\u00eat\">Hyst\u00e9r\u00e9sis d\u2019arr\u00eat<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La pompe du circuit de chauffage est d\u00e9sactiv\u00e9e lorsque la temp\u00e9rature ambiante r\u00e9elle est sup\u00e9rieure \u00e0 la temp\u00e9rature ambiante nominale plus l&rsquo;hyst\u00e9r\u00e9sis d&rsquo;arr\u00eat.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"Valeurs-de-sortie\" style=\"font-size:30px\"><strong>Valeurs de sortie<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"\u00c9tat-pompe-1\">\u00c9tat pompe 1<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cette sortie num\u00e9rique fait r\u00e9f\u00e9rence \u00e0 la pompe \u00e0 r\u00e9gler dans le circuit de chauffage. S\u00e9lectionnez la pompe correspondante dans la liste.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"\u00c9tat-commutation-2-(En-option)\">\u00c9tat commutation 2 (En option)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cette sortie num\u00e9rique commute de la m\u00eame mani\u00e8re que la sortie de la pompe de l&rsquo;\u00e9tat 1. Un composant suppl\u00e9mentaire peut \u00eatre r\u00e9gl\u00e9 avec cette sortie. Pour la vanne de commutation, \u00ab\u00a0logique un\u00a0\u00bb signifie que la sortie \u00ab\u00a0X\u00a0\u00bb de la vanne m\u00e9langeuse est ouverte. S\u00e9lectionnez le composant correspondant dans la liste, selon les besoins.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"D\u00e9bit-r\u00e9gl\u00e9\">D\u00e9bit r\u00e9gl\u00e9<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">La valeur sp\u00e9cifi\u00e9e pour \u00ab\u00a0D\u00e9bit nominal\u00a0\u00bb est transf\u00e9r\u00e9e \u00e0 la pompe ici. S\u00e9lectionnez le d\u00e9bit de la pompe correspondante dans la liste. Cette sortie n&rsquo;est active que si \u00ab\u00a0R\u00e9glage du d\u00e9bit\u00a0\u00bb est activ\u00e9 dans le champ \u00ab\u00a0d\u00e9bit d\u00e9terminant\u00a0\u00bb de la pompe \u00e0 r\u00e9gler, sinon les r\u00e9glages de la pompe ont priorit\u00e9 sur les sorties de r\u00e9glage analogiques. Double-cliquez sur la pompe pour v\u00e9rifier et modifier ces param\u00e8tres.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\" id=\"Vanne-m\u00e9langeuse-(En-option)\">Vanne m\u00e9langeuse (En option)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">En fonction de la temp\u00e9rature ext\u00e9rieure et de la temp\u00e9rature aller nominale du convecteur, la temp\u00e9rature aller requise est calcul\u00e9e et la position de la vanne m\u00e9langeuse est r\u00e9gl\u00e9e en cons\u00e9quence. La temp\u00e9rature aller calcul\u00e9e est limit\u00e9e \u00e0 un maximum de la temp\u00e9rature aller nominale et \u00e0 un minimum de la temp\u00e9rature ambiante nominale plus 10\u00b0C.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"Vue-d'ensemble-des-d\u00e9pendances-du-r\u00e9glage\" style=\"font-size:30px\"><strong>Vue d&rsquo;ensemble des d\u00e9pendances du r\u00e9glage<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tableau: D\u00e9pendances du r\u00e9glage<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Sorties<\/td><td>Param\u00e8tre<\/td><td>Note<\/td><td>Entr\u00e9es<\/td><td>Fonction<\/td><\/tr><tr><td>Y1: \u00c9tat pompe Y1 = Y2 Y2: Etat commutation 2<\/td><td rowspan=\"2\">Sans vanne m\u00e9langeuse<\/td><td rowspan=\"2\"><em>R\u00e9gler la pompe sur<br>&#8211;<\/em> <em>D\u00e9bit nominal<\/em><\/td><td rowspan=\"2\">X1: Temp\u00e9rature ext\u00e9rieure <br>X2: Temp\u00e9rature ambiante nominale <br>X3: Temp\u00e9rature ambiante r\u00e9elle <br>X4: D\u00e9bit nominal<\/td><td>Y1=0 si X3 &gt; X2 + Hyst\u00e9r\u00e9sis d&rsquo;arr\u00eat [\u00b0C] Y1=1 si X3 &lt; X2 + Hyst\u00e9r\u00e9sis mise en marche [\u00b0C]<\/td><\/tr><tr><td>Y3: D\u00e9bit nominal<\/td><td>Y3 = D\u00e9bit nominal X4<\/td><\/tr><tr><td>Y1: \u00c9tat pompe Y1 = Y2 Y2: Etat commutation 2<\/td><td rowspan=\"3\">Avec vanne m\u00e9langeuse<\/td><td rowspan=\"3\"><em>R\u00e9gler la pompe sur<br>&#8211;<\/em> <em>D\u00e9bit nominal<br><br>R\u00e9gler la vanne m\u00e9langeuse sur<\/em> <em>\u2013<\/em> <em>Valeur contr\u00f4l\u00e9<\/em><\/td><td rowspan=\"3\">X1: Temp\u00e9rature ext\u00e9rieure <br>X2: Temp\u00e9rature ambiante nominale <br>X3: Temp\u00e9rature ambiante r\u00e9elle <br>X4: D\u00e9bit nominal <br>X5: Temp\u00e9rature nominal variable <br>X6: Niveau de temp\u00e9rature sup\u00e9rieure <br>X7: Niveau de temp\u00e9rature inf\u00e9rieure<\/td><td>Y1=0 si X3 &gt; X2 + Hyst\u00e9r\u00e9sis d&rsquo;arr\u00eat [\u00b0C] Y1=1 si X3 &lt; X2 + Hyst\u00e9r\u00e9sis mise en marche [\u00b0C]<\/td><\/tr><tr><td>Y3: D\u00e9bit nominal<\/td><td>Y3 = D\u00e9bit nominal X4<\/td><\/tr><tr><td>Y4: \u00c9tat vanne m\u00e9langeuse<\/td><td>Y4 = f(X5, X6, X7)<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"author":19748,"featured_media":0,"parent":118282,"menu_order":47,"comment_status":"closed","ping_status":"closed","template":"","class_list":["post-118320","handbuch","type-handbuch","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.0 (Yoast SEO v28.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>R\u00e9glage du circuit de chauffage - POLYSUN<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"R\u00e9glage du circuit de chauffage\" \/>\n<meta property=\"og:description\" content=\"Le r\u00e9glage du circuit de chauffage r\u00e9gule l&rsquo;\u00e9tat et le d\u00e9bit d&rsquo;une pompe en...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/\" \/>\n<meta property=\"og:site_name\" content=\"POLYSUN\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/polysun.switzerland\/\" \/>\n<meta property=\"article:modified_time\" content=\"2023-10-25T15:21:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.velasolaris.com\/wp-content\/uploads\/2023\/10\/image138-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"326\" \/>\n\t<meta property=\"og:image:height\" content=\"119\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/handbuch\\\/polysun-designer\\\/reglages\\\/reglage-du-circuit-de-chauffage\\\/\",\"url\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/handbuch\\\/polysun-designer\\\/reglages\\\/reglage-du-circuit-de-chauffage\\\/\",\"name\":\"R\u00e9glage du circuit de chauffage - POLYSUN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/handbuch\\\/polysun-designer\\\/reglages\\\/reglage-du-circuit-de-chauffage\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/handbuch\\\/polysun-designer\\\/reglages\\\/reglage-du-circuit-de-chauffage\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.velasolaris.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/figure145.png\",\"datePublished\":\"2023-08-25T05:26:20+00:00\",\"dateModified\":\"2023-10-25T15:21:10+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/handbuch\\\/polysun-designer\\\/reglages\\\/reglage-du-circuit-de-chauffage\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/handbuch\\\/polysun-designer\\\/reglages\\\/reglage-du-circuit-de-chauffage\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/handbuch\\\/polysun-designer\\\/reglages\\\/reglage-du-circuit-de-chauffage\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.velasolaris.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/figure145.png\",\"contentUrl\":\"https:\\\/\\\/www.velasolaris.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/figure145.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/handbuch\\\/polysun-designer\\\/reglages\\\/reglage-du-circuit-de-chauffage\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Polysun Designer\",\"item\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/handbuch\\\/polysun-designer\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"R\u00e9glages\",\"item\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/handbuch\\\/polysun-designer\\\/reglages\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"R\u00e9glage du circuit de chauffage\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/\",\"name\":\"POLYSUN\",\"description\":\"by Vela Solaris\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/#organization\",\"name\":\"POLYSUN\",\"url\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.velasolaris.com\\\/wp-content\\\/uploads\\\/2020\\\/07\\\/Polysun-Logo.svg\",\"contentUrl\":\"https:\\\/\\\/www.velasolaris.com\\\/wp-content\\\/uploads\\\/2020\\\/07\\\/Polysun-Logo.svg\",\"width\":1,\"height\":1,\"caption\":\"POLYSUN\"},\"image\":{\"@id\":\"https:\\\/\\\/www.velasolaris.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/polysun.switzerland\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/vela-solaris\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"R\u00e9glage du circuit de chauffage - POLYSUN","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/","og_locale":"fr_FR","og_type":"article","og_title":"R\u00e9glage du circuit de chauffage","og_description":"Le r\u00e9glage du circuit de chauffage r\u00e9gule l&rsquo;\u00e9tat et le d\u00e9bit d&rsquo;une pompe en...","og_url":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/","og_site_name":"POLYSUN","article_publisher":"https:\/\/www.facebook.com\/polysun.switzerland\/","article_modified_time":"2023-10-25T15:21:10+00:00","og_image":[{"width":326,"height":119,"url":"https:\/\/www.velasolaris.com\/wp-content\/uploads\/2023\/10\/image138-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/","url":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/","name":"R\u00e9glage du circuit de chauffage - POLYSUN","isPartOf":{"@id":"https:\/\/www.velasolaris.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/#primaryimage"},"image":{"@id":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/#primaryimage"},"thumbnailUrl":"https:\/\/www.velasolaris.com\/wp-content\/uploads\/2023\/10\/figure145.png","datePublished":"2023-08-25T05:26:20+00:00","dateModified":"2023-10-25T15:21:10+00:00","breadcrumb":{"@id":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/#primaryimage","url":"https:\/\/www.velasolaris.com\/wp-content\/uploads\/2023\/10\/figure145.png","contentUrl":"https:\/\/www.velasolaris.com\/wp-content\/uploads\/2023\/10\/figure145.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/reglage-du-circuit-de-chauffage\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.velasolaris.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Polysun Designer","item":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/"},{"@type":"ListItem","position":3,"name":"R\u00e9glages","item":"https:\/\/www.velasolaris.com\/fr\/handbuch\/polysun-designer\/reglages\/"},{"@type":"ListItem","position":4,"name":"R\u00e9glage du circuit de chauffage"}]},{"@type":"WebSite","@id":"https:\/\/www.velasolaris.com\/fr\/#website","url":"https:\/\/www.velasolaris.com\/fr\/","name":"POLYSUN","description":"by Vela Solaris","publisher":{"@id":"https:\/\/www.velasolaris.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.velasolaris.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.velasolaris.com\/fr\/#organization","name":"POLYSUN","url":"https:\/\/www.velasolaris.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.velasolaris.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.velasolaris.com\/wp-content\/uploads\/2020\/07\/Polysun-Logo.svg","contentUrl":"https:\/\/www.velasolaris.com\/wp-content\/uploads\/2020\/07\/Polysun-Logo.svg","width":1,"height":1,"caption":"POLYSUN"},"image":{"@id":"https:\/\/www.velasolaris.com\/fr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/polysun.switzerland\/","https:\/\/www.linkedin.com\/company\/vela-solaris\/"]}]}},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.velasolaris.com\/fr\/wp-json\/wp\/v2\/handbuch\/118320","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.velasolaris.com\/fr\/wp-json\/wp\/v2\/handbuch"}],"about":[{"href":"https:\/\/www.velasolaris.com\/fr\/wp-json\/wp\/v2\/types\/handbuch"}],"author":[{"embeddable":true,"href":"https:\/\/www.velasolaris.com\/fr\/wp-json\/wp\/v2\/users\/19748"}],"replies":[{"embeddable":true,"href":"https:\/\/www.velasolaris.com\/fr\/wp-json\/wp\/v2\/comments?post=118320"}],"version-history":[{"count":0,"href":"https:\/\/www.velasolaris.com\/fr\/wp-json\/wp\/v2\/handbuch\/118320\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.velasolaris.com\/fr\/wp-json\/wp\/v2\/handbuch\/118282"}],"wp:attachment":[{"href":"https:\/\/www.velasolaris.com\/fr\/wp-json\/wp\/v2\/media?parent=118320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}