System and Component Results


System Results

The results of the various loops are listed in this window. In the overview there are the solar fractions as well as the respective energies and how they are determined.

Table: Results of the various loops

DescriptionAbbrev.Meaning
Energy consumptionQuseAmount of energy actually consumed by a consumer unit. This includes energy consumption for domestic hot water, swimming pool, building heating and cooling as well as heat sink, provided the latter is a consumer unit. All values are added to a total amount (positive values).
Energy demandQdemAmount of energy required by consumer units to ensure that the required comfort conditions are met. This includes energy demand for domestic hot water, building heating and cooling as well as heat sink, provided the latter is a consumer unit. All values are added to a total amount (positive values).
Energy supplied from heat generators to system   (inclusive of air-conditioning devices)QauxAmount of energy supplied from electrical and fuel-operated heat generators and electrical air-conditioning devices to fluid.
Fuel and power consumption by heat generators and air-conditioning devicesEauxAmount of fuel and electrical power required by heat generators and electrical air-conditioning devices.
Overall fuel and electrical power consumptionEtotAmount of fuel and electrical power required by heat generators, electrical air-conditioning devices, pumps, fans, etc.

Component Results

The results of each individual component are shown in average monthly and annual values, as well as maximum and minimum values. These latter values are useful above all for the pipes, in which the average temperature has less importance than the effective temperature at the time of flow. This visualization is possible at the Professional and the Designer level.